Living Space Control
Model 70 Living Space Control
Owner’s Manual
For use with Model 1700 Whole-Home Dehumidifier
Non-Programmable
READ AND SAVE THESE INSTRUCTIONS
Download from Www.Somanuals.com. All Manuals Search And Download.
TO TURN THE MODEL 1700 DEHUMIDIFIER ON
Press the “ON” button to enable the Model 1700 Dehumidifier to operate. When the “ON” button is
pressed, the display will show a solid “ON”. When the Model 1700 Dehumidifier is actually running,
“ON” will blink. NOTE: After initial power-up, the dehumidifier will not run until 2 minutes have
elapsed for system initialization.
TO TURN THE MODEL 1700 DEHUMIDIFIER OFF
Press the “OFF” button to turn the Model 1700 Dehumidifier off. When the “OFF” button is pressed, the
word “ON” will disappear from the display. (NOTE: turning the Living Space Control off will still allow
the Model 1700 Dehumidifier to run fan cycling, if enabled on the Model 1700 Main Control. Please see
page 3 of the Model 1700 Owner’s Manual.)
TO ADJUST THE MODEL 1700 DEHUMIDIFIER SET POINT
Press the ꢀꢁ buttons to ADJUST the dryness level set point for
OR
the Model 1700 Dehumidifier. When either of the ꢀꢁ buttons
is first pressed, the display will show “MORE DRY” and “LESS
DRY” on the display with the current set point.
For increased dehumidification, pressing the ꢀ button will increase the dryness level towards
“MORE DRY”, up to a maximum of 7 bars. When the ꢀ button is pressed, “LESS DRY” disappears from
the display and only “MORE DRY” is displayed. Each button depression will add 1 bar to the display.
For decreased dehumidification, pressing the ꢁ button will decrease the dryness level towards
“LESS DRY”, down to a minimum of 1 bar. When the ꢁ button is pressed, “MORE DRY” disappears from
the display and only “LESS DRY” is displayed. Each button depression will remove 1 bar from the display.
Based on the thermostat set point, use the following table to determine the set point to reach a desired
RH value. The Model 1700 Dehumidifier will work to achieve these values.
EXAMPLE: At an indoor
temperature of 75°F with a
setting of 3 BARS – NORMAL,
the dehumidifier will work to
achieve an RH value of 53%.
%RH ( 5%) based on Set Point Bar Display and Indoor Temperature
Indoor Temperature (°F)
Set Point
Bar Display
65
70
75
80
1 BAR – “LESS DRY”
2 BARS
84%
73%
63%
54%
46%
39%
34%
71%
61%
53%
45%
39%
33%
28%
60%
52%
45%
39%
33%
28%
24%
NOTES:
86%
74%
64%
55%
47%
40%
1. %RH values are 5% and
are to be used as a GUIDE
ONLY for initial set-up.
2. Indoor Temperature is
measured by the Model 70
Living Space Control.
3 BARS – “NORMAL”
4 BARS
5 BARS
6 BARS
7 BARS – “MORE DRY”
NOTE: In the event of a power failure, the Living Space Control will hold the last set point level
in memory indefinitely.
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING THE LIVING SPACE CONTROL
If the surface of the Living Space Control becomes dirty, it can be cleaned with plain water or a
non-abrasive household cleaner, including glass cleaner. When using any cleaner, be careful not to get
any into the interior of the control. Do not spray any liquid directly onto the control. Spray the
cleaner onto a soft cloth and wipe the surface of the control gently.
IV. LIMITED WARRANTY
®
Your Research Products Corporation Aprilaire Model 70 Living Space Control is expressly warranted for two (2) year
from date of installation to be free from defects.
Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a
replacement for the Living Space Control which is found to be defective within two (2) year period and which is returned
not later than thirty (30) days after said two (2) year period by you to either your original supplier or to Research
Products Corporation, Madison, Wisconsin 53701, together with the installation date of the Living Space Control.
THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL
NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO
DEFECTS IN THE LIVING SPACE CONTROL ITSELF.
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN
DURATION TO THE AFORESAID ONE YEAR PERIOD. RESEARCH PRODUCTS CORPORATION’S LIABILITY FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH
OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS
LIMITED WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED BY A QUALIFIED
HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A
QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental
or consequential damages so the above exclusion or limitations may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
WARRANTY REGISTRATION
Please… Take a few minutes to visit us on-line at
to register your Aprilaire product.
If you do not have on-line access, please mail a postcard with your name,
address, phone number, product purchased and date of purchase to:
Research Products Corporation
P.O. BOX 1828
Madison, WI 53701
Thank you!
Your Warranty Registration information will not be sold or shared outside of this company.
10006368
B2203507
1015 E. WASHINGTON AVE. • MADISON, WI 53703 • PHONE: 608/257-8801 • FAX: 608/257-4357 • www.aprilaire.com
Download from Www.Somanuals.com. All Manuals Search And Download.
|