Aprilaire Air Cleaner 1210 User Manual

Media Air Cleaners  
Installation Instructions  
WARNING  
CAUTION  
1. High voltage may cause serious  
injury from electrical shock.  
Disconnect power to the  
furnace/air handler before  
starting installation.  
2. Sharp edges may cause injury  
from cuts. Use care when cutting  
and handling sheet metal.  
1. To prevent component failure, do not install the air cleaner on the warm  
air supply or in an area where the temperature may exceed 140°F. This  
may include areas above heat exchangers in downflow furnaces or above  
exhaust flues in lowboy furnace cold air returns.  
2. Installation must be done by a qualified heating and air conditioning  
professional. Read instructions thoroughly before beginning installation.  
3. Do not install air cleaner downstream of a UV light. UV lamps will cause  
degradation of the filtering media.  
SPECIFICATIONS  
Airflow Capacity: up to 2000 CFM maximum  
Max. Equipment Weight:  
Cabinet will support 400 lb. static load  
Replacement Media:  
1210, 2210, 3210: Model 210 or 213 with SelfSeal™  
1310, 2310, 3210: Model 310 or 313 with SelfSeal™  
1410, 2410, 3410: Model 410 or 413 with SelfSeal™  
Air Cleaner Operating Environment:  
Temperature: 0°F – 140°F  
Humidity: 0-90% non-condensing  
DIMENSIONS  
E
B
D
with door  
without door  
C
F
A
G H  
90-1333  
TABLE 1 – Dimensions (inches)  
Model  
A
B
C
D
E
F
G
H
1210, 2210, 3210  
1310, 2310, 3310  
1410, 2410, 3410  
19-3/4  
18-1/16  
15-7/16  
25-3/8  
20-1/16  
28-1/16  
21-3/16  
15-7/8  
23-7/8  
6-3/4  
6-3/4  
6-3/4  
27-3/8  
22-1/16  
30-1/16  
21-3/16  
15-7/8  
23-7/8  
19-3/4  
18-1/16  
15-7/16  
22-1/16  
20-3/8  
17-3/4  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Expand Contents

INSTALLATION  
1. Disconnect power to the furnace or air handler at the electrical service panel.  
FIGURE 5  
WARNING  
120 Volts may cause serious injury from electrical shock. Disconnect  
power to the furnace/air handler before starting installation. Leave power  
disconnected until installation is completed.  
2. Remove the air cleaner door from the outer housing and pull out the filtering media.  
3. If replacing an existing filter, remove the filter and thoroughly clean the blower  
compartment.  
90-1374  
4. Use screws (field supplied) to mount the outer housing to the furnace/air handler.  
There is no inlet or outlet side on the outer housing (the outer housing can be mounted  
on the left or right side of the furnace/air handler).  
NOTE FOR UPFLOW INSTALLATIONS: Provide support under the outer housing to ensure the quality of the seals (see Figure 5).  
5. Mount the return ductwork to the outer housing.  
FIGURE 6  
6. Seal all connections using mastic, foil tape or silicone based caulk.  
7. Install the filtering media (see Figure 6).  
8. Install the door.  
9. Reconnect power to the furnace or air handler at the electrical  
service panel.  
Expand clean filter.  
Install filter with Air Flow pointing  
toward Furnace or Air Handler.  
Align filter in top and bottom rails  
and slide into place. Reinstall door.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 • www.aprilairepartners.com  
10009757 1.12  
B2701229A  
Printed in U.S.A.  
© 2012 Aprilaire – A division of Research Products Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Aprilaire Video Gaming Accessories 8620 User Manual
Aprilaire Thermostat Thermostat User Manual
Aprilaire Thermostat 8600 User Manual
Aprilaire Thermostat 8554 User Manual
Aprilaire Humidifier 700m User Manual