Aprilaire Dehumidifier 1750A 1770A User Manual

Model 1750A/1770A Dehumidifier  
Owner’s Manual  
PLEASE LEAVE THIS MANUAL WITH THE HOMEOWNER  
Installed by:_________________________________ Installer Phone: _______________________ Date Installed:_______________  
Filter  
Access  
Humidity  
Control  
Filter  
Access  
Inlet  
Outlet  
Drain  
On/Off Switch  
Thank you for your purchase of the Aprilaire® Dehumidifier. Your dehumidifier is designed to remove humidity from your home, maintaining the  
humidity at a comfortable level and reducing the unwanted effects of high humidity. Use your Aprilaire Dehumidifier to control the humidity that  
comes into the home from opening doors and infiltration (i.e. outdoor air entering through the building envelope). You can reduce the amount of  
humidity that enters the home by closing windows, doors, and fireplace flues when the outdoor humidity is high and by drying clothes outside.  
Whirlpool tubs and saunas will also increase the amount of humidity in the home. Direct exhaust from kitchen vents and bath fans is the best  
means of controlling humidity due to cooking and showers/baths. Your Aprilaire Dehumidifier is not designed for pool rooms or to eliminate or  
reduce condensation on windows in the winter and works best when the indoor temperature is above 65°F (18°C).  
WHOLE HOME DEHUMIDIFICATION  
The Aprilaire Dehumidifier controls the humidity level in your entire home. A powerful blower inside the dehumidifier draws air into the cabinet,  
filters and removes moisture from the air, and then discharges the dry air to the home. Inside the cabinet, a sealed refrigeration system removes  
moisture by moving the air through a series of tubes and fins that are kept colder than the dew point of the incoming air. The dew point is  
the temperature at which moisture in the air will condense, much like what occurs on the outside of a cold glass on a hot summer day. The  
condensed moisture drips into the dehumidifier drain pan to a drain tube routed to the nearest floor drain – no need to empty a tub every day.  
After the moisture is removed, the air moves through a second coil where it is reheated before being sent back into the home. It is normal for the  
air leaving the dehumidifier to be warmer than the air entering the dehumidifier.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Expand Contents

OPTIONAL – TWO zONE DEHUMIDIFICATION  
The dehumidifier can be installed to dehumidify just one area or zone  
(i.e. the whole home) or, as shown in the illustration to the right, can  
be installed to dehumidify two separate areas or zones (i.e. the home  
and the basement) independently. Each zone can have its own humidity  
level setting/control when installed with the Model 76 Control or Model  
8910 Home Comfort Control, or the two zones can share the same  
setting/control. You and your installing contractor determine which zone  
is the most important to control and this becomes the “Primary” zone  
while the other is the “Secondary” zone. The dehumidifier will turn  
on and open/close dampers to direct the dry air and satisfy the needs  
of the Primary zone. If there is no demand from the Primary zone, the  
Secondary zone will be dehumidified. Contact your installing contractor  
for details about Primary/Secondary Zoned Dehumidification.  
TO/FROM  
PRIMARY ZONE  
DAMPERS  
DAMPERS  
TO  
SECONDARY  
ZONE  
FROM  
SECONDARY  
ZONE  
90-1536  
HOW DOES THE DEHUMIDIFIER WORK?  
When the dehumidifier turns on, the blower circulates the air for three (3) minutes before measuring the  
humidity level of the air. The green status light below the control setting flashes when the dehumidifier is  
circulating the air. If the humidity of the air is higher than the setting, the compressor turns on and the green  
Status light is lit continuously. The dehumidifier turns off after the humidity level of the air has dropped  
below the setting.  
OPTIONAL – HEATINg AND COOLINg SySTEM BLOWER OPERATION  
Your installing contractor may have configured the dehumidifier to turn on the heating and cooling system  
blower when the dehumidifier turns on to allow for improved circulation of the dry air.  
90-1561  
HOW DOES THE OPTIONAL VENTILATION WORK?  
With the ventilation option installed (if you are unsure if this option has been installed, contact your installing contractor), the dehumidifier will  
bring in outside air for the amount of time set on the Cycle Time adjustment during the set Cycle Period.  
Your dehumidifier will work with your heating and cooling system blower to satisfy the ventilation requirements that have been set. For example,  
if the Cycle Time is set for 20 minutes and the Cycle Period for 1 hour, you will get outdoor air introduced to your home for 20 minutes every hour.  
When your heating and cooling system blower operates the dehumidifier blower will turn on and will open a normally-closed damper in the duct  
that brings in outdoor air. If it is getting close to the end of the Cycle Period and your heating and cooling system blower has not operated, the  
dehumidifier will turn on the system blower. Using the 20 minute per hour settings as an example, if the heating or cooling comes on for only  
10 minutes, the dehumidifier control will turn on the system blower for the final 10 minutes of the 1-hour cycle period to deliver the required  
amount of fresh air.  
Outdoor air that is brought in will mix with the air circulating through your heating and cooling system. The dehumidifier will monitor the air in  
your home and if the humidity level gets higher than the setting, it will turn on the compressor to remove the moisture.  
An outdoor sensor, if installed with the ventilation option, will monitor the temperature of the outdoor air and if the temperature exceeds 100°F  
(38°C) or drops below 0°F (-18°C) ventilation will not occur. If the outdoor temperature is between 20°F (-7°C) and 0°F (-18°C), ventilation will  
only occur when your heating system operates.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
CLEAN OR REPLACE THE AIR FILTER  
CHECK THE DRAIN  
After initial installation, check the air filter after 6 months.  
If it appears matted with dust, pet hair or other debris,  
maintain a 6-month cleaning schedule. If it appears  
clean or lightly loaded, maintain a 12-month cleaning  
schedule. Replacement filters are Aprilaire Part No. 4510  
and can be purchased from your installing contractor.  
The drain should be checked annually to ensure there is no blockage or air lock in  
the drain system. If the unit is not properly draining, have it checked by a qualified  
service professional.  
Procedure to Check Drain System  
1. Turn the ON/OFF switch OFF.  
2. Remove the filter access door from  
either side of the dehumidifier.  
EVAPORATOR  
COIL  
Filter Cleaning Procedure  
1. Turn the ON/OFF switch OFF.  
2. Remove the filter access door from either side of the  
dehumidifier.  
3. Slide the filter out of the dehumidifier.  
4. Flush the filter with warm water and a mild detergent  
solution.  
3. Slide the filter out of the dehumidifier  
to expose the evaporator coil.  
4. Slowly pour a pint of water into the  
dehumidifier drip pan near the bottom  
of the evaporator coil so that the  
water flows into the drain pan.  
DRIP PAN  
5. Shake off the excess water from the filter.  
6. Replace the filter – make sure the filter seats in both  
the top and bottom filter rails.  
7. Replace the filter access door.  
8. Turn the ON/OFF switch ON.  
5. Check where the drain piping flows  
into the floor drain. If water does  
not flow out, the unit is not properly  
draining.  
6. Turn on the ON/OFF switch ON.  
FILTER RAIL  
90-1558  
CAUTION  
Do not use spray solvents or cleaners on or near the inlet side of the dehumidifier.  
If desired, apply cleaner to a cloth and use to clean the cabinet.  
LIMITED WARRANTy  
Your Research Products Corporation Aprilaire® Dehumidifier is expressly warranted for five (5) years from date of installation to be free from defects in materials or workmanship.  
Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any component which is found to be defective within such five (5) year period  
and which is returned not later than thirty (30) days after said five (5) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701, together with the  
model number and installation date of the dehumidifier.  
THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR  
INSTALLER AS CONTRASTED TO DEFECTS IN THE DEHUMIDIFIER ITSELF.  
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD. RESEARCH PRODUCTS  
CORPORATION’S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED  
WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED BY A QUALIFIED  
HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE  
EFFECTIVE UPON INSTALLATION.  
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above exclusion or limitations may not apply to you.  
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.  
WARRANTy REgISTRATION  
Visit us on-line at www.aprilaire.com to register your Aprilaire product. If you do not have on-line access, please mail a postcard with your  
name, address, phone number, email address, product purchased, model number, date of purchase and dealer name and address to:  
Research Products Corporation, P.O. Box 1467, Madison, WI 53701  
your Warranty Registration information will not be sold or shared outside of this company.  
P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 • www.aprilaire.com  
10009844 2.12  
B2205732A  
Printed in U.S.A.  
© 2012 Aprilaire – A division of Research Products Corporation  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  

Aprilaire Video Gaming Accessories 8620 User Manual
Aprilaire Thermostat Model 8570 User Manual
Aprilaire Thermostat 8551 User Manual
Aprilaire Thermostat 8533 User Manual
Aprilaire Humidifier 350 User Manual