Model 60 shown.
Automatic
Digital Humidifier Control
Model 60 & 62
Safety and Installation Instructions
READ COMPLETE INSTALLATION INSTRUCTIONS
AND TEMPLATE BEFORE STARTING INSTALLATION.
WARNING
ATTENTION INSTALLER: This product must be
installed by a qualified heating and air conditioning
contractor. Failure to do so could result in serious
injury from electrical shock.
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
Figure B
Use the “OFF” setting for Model 800
Series humidifiers.
STEP 1: Unpack the Humidifier Control Carton
Make sure all components are present (see Figure A):
Use Setting “A”
A. Humidifier Control
B. Outdoor Temperature Sensor
C. Manual Mode Label
for Model 400 Series
humidifiers in areas
with very hard water.
The indicator will light
after 150 hours of
Water Panel
Indicator
Settings
humidifier operation.
A
C
Use Setting “B”
for Model 400 Series,
and for 500 Series, 600
Series and 700 Series
humidifiers in areas
with very hard water.
The indicator will light
after 300 hours of
B
Figure A
90-1201B
humidifier operation.
STEP 2: Disassemble the Humidifier Control
Use Setting “C” for Model 500 Series,
600 Series and 700 Series humidifiers.
The indicator will light after 600 hours of
humidifier operation.
Remove the knob. Remove the cover by pulling at the bottom and
swinging it out and upward.
90-1202B
STEP 3: Check the Change Water Panel Indicator Setting
This setting will control when the indicator light turns on,
reminding you to change your water panel. If your Control came
with a humidifier, the Control is pre-set for the humidifier. If the
installation site has a 3-month or shorter heating season or very
hard water, you may want to adjust the setting (see Figure B).
The Model 62 shipped with the Model 800 Steam Humidifier is
factory set to “OFF”. The Model 62 does not have the “Change
Water Panel” light on the Control. The Canister Change indicator
for the Model 800 is on the humidifier.
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
DUCT (SHEET METAL) MOUNT:
STEP 4: Determine Location for Humidifier Control
and Mount Control
After location for Control is selected, drill a 3/4 inch hole for the
RH sensor (the RH sensor extends from the back of the
Humidifier Control).
Humidifier Control must be mounted on the Return Duct, at least
6 inches upstream of the following (see Figure C):
Use 2 sheet metal screws, 3/4 inch long (not provided), to mount
the Humidifier Control. Use the mounting slot to level the Control,
then secure the Control with the second sheet metal screw.
• Humidifier
• Humidifier Bypass Ductwork (if applicable)
• Fresh Air Intake Ductwork (if applicable)
Make sure the Humidifier Control sensor gasket is seated tightly
around the drilled hole. Do not install Control without gasket.
Ambient operating temperature of the Humidifier Control is to be
from 20°F to 120°F to prevent damage to the control display.
DUCT (FIBER BOARD) MOUNT:
After location for Control is selected, cut a rectangular hole in
the duct board, no smaller than 6-9/16 inches long by 4-3/8
inches wide.
RETURN
DUCT
6" MIN.
HUMIDIFIER
CONTROL
Cut a rectangular piece of sheet metal to fit behind the hole in
duct board for mounting the Humidifier Control.
HUMIDIFIER
Drill a 3/4 inch hole for the RH sensor (the RH sensor extends from
the back of the Humidifier Control) into the sheet metal plate.
COIL
FRESH AIR
INTAKE
Use 2 sheet metal screws, 3/4 inch long (not provided), to mount
the Humidifier Control.
BYPASS
CONNECTION
Make sure the Humidifier Control sensor gasket is seated tightly
around the drilled hole. Do Not Install Control Without Gasket.
Figure C
Secure the sheet metal plate, with the Humidifier Control
mounted, inside the duct (see Figure D).
90-1137
CONTROL REPLACEMENT:
When replacing an existing control, the duct opening left by the
removed control must be covered completely. Locate and install
the new control as instructed previously in Step 4.
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure D – Fiber Board Duct Mount
Figure E – Digital Humidifier Control 24V Terminals
CONTROL BOARD
COVER
GASKET
SCREW (x2)
R
C
A
B
ODT
W
G
H
H
Gf
KNOB
INSIDE OF
RETURN
DUCT
OUTDOOR
TEMPERATURE
SENSOR
FAN SIGNAL
TO HVAC
EQUIPMENT
BASE PLATE
SHEET METAL PLATE
COMMUNICATION
WITH APRILAIRE
8570 THERMOSTAT
HEAT SIGNAL
FROM HVAC
EQUIPMENT
SOLENOID
CONTROL
OUTPUT
RETURN DUCT
RETURN
DUCT
SHEET METAL
PLATE
CUT OPENING IN
RETURN DUCT
24 VAC FROM
HVAC EQUIPMENT
“R” AND “C”
FAN SIGNAL
FROM
THERMOSTAT
90-1203B
90-1397B
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.
STEP 5: Determine Location for Outdoor
Temperature Sensor
STEP 7: Alternate Location for Outdoor
Temperature Sensor
The location of the Outdoor Temperature Sensor must meet
these three requirements:
WARNING
If Outdoor Temperature Sensor is mounted in an intake
duct or pipe, do not set Blower Activation switch to “ON”.
1. Must be mounted on North, East or West side of house out of
direct sunlight.
2. Must be at least 3 feet from all exhaust vents.
The Sensor can also be mounted in the center of either:
3. Must be above expected snow line (see Figure F).
• PVC fresh air intake pipe for the HVAC system
OR
Incorrect humidity levels will result if these requirements are not
met.
• fresh air intake duct. Mount the sensor with a #8 galvanized
screw.
In both cases, the Sensor must be no more than 3 feet
from the outside wall. See Figure G.
Figure F
NORTH, EAST
OR WEST SIDE
OF HOME
OUTDOOR
TEMPERATURE
SENSOR
If it is not feasible to use the Outdoor Temperature Sensor in any
of the ways described, the Humidifier Control can be installed for
Manual Operation. See “Installing the Humidifier Control for
Manual Operation” and Figure J for details.
SENSOR
SENSOR
BRACKET
Figure G
OUTDOOR
TEMPERATURE SENSOR
LEADS
ABOVE EXPECTED
SNOW LINE
CENTER LINE
90-998
3 FEET MAX.
STEP 6: Locate Existing Access Hole to Outside
A convenient way to get the Sensor wire outside is to make use
of unused wires running to the A/C condensing unit (if
applicable). Other ways are to use existing holes for Cable TV
lines, telephone lines, A/C lines, etc. Read all equipment
instructions beforehand for possible conflicts and warnings.
OUTSIDE WALL
90-999
10
11
Download from Www.Somanuals.com. All Manuals Search And Download.
When the Blower Activation switch is “ON”, the Humidifier
Control may periodically turn the HVAC blower on to sample the
humidity of the air.
STEP 8: Route the Wire from Control to Sensor
Run wire to the outdoor temperature sensor. Sensor is not
affected by lead lengths less than 300 feet.
Installing the Humidifier Control for
Manual Operation
If it is not feasible to install the Outdoor Temperature
Sensor, the Humidifier Control can be operated in
Manual Mode.
CAUTION
Do not run outdoor temperature sensor alongside
wires carrying high voltage (120 VAC or higher).
Secure the sensor bracket with a #8 screw.
1. Position the Mode Switch in the “MAN” position.
Manual indicator “M” will be displayed.
STEP 9: Attach Sensor Wire to Humidifier Control
Strip wire 1/4 inch, and insert the wires from the Sensor into the
terminals labeled “ODT” on the Humidifier Control. See Figure H
for location of terminals.
2. Apply the Manual Mode Label to the cover,
aligning the sticker and knob holes.
Figure J
Figure H
90-1219B
BLOWER ACTIVATION
Set the Blower Activation Switch to “ON” to allow the Humidifier
Control to activate the furnace fan for additional humidification.
This may be required if the humidifier is mounted on a heat pump
or a furnace with short run cycles.
When the Blower Activation switch is “ON”, the Humidifier
Control will turn on the HVAC blower when humidity is required.
In the “OFF” position, the humidifier will only operate if humidity
is required and the HVAC system is operating.
90-1236B
12
13
Download from Www.Somanuals.com. All Manuals Search And Download.
• Wire “Gf” on the Model 60 to “G” on the furnace terminal
strip.
STEP 10: Model 60 Wiring for Model 400, 500, 600 and
700 Series Humidifiers – See Figure K
• Wire “W” on the Model 60 to “W” on the furnace terminal
strip.
WARNING
120 volts may cause serious injury from electrical
shock. Disconnect electrical power to the furnace
before starting installation.
• Replace cover and knob.
Figure K – Model 60 Wiring for Model 400, 500, 600
and 700 Series Humidifiers
Strip the wires used for all Humidifier Control terminal
connections 1/4 inch.
NOTES:
ADHC TERMINAL STRIP
POWER
INPUTS
OUTPUTS
• The Model 60 must be continuously powered from “R” and
“C” on the furnace to function properly.
R
C
A
B
ODT
W
G
H
H
Gf
NORTH, EAST
OR WEST SIDE
OF HOME
• The minimum VA required is 2.0 VA.
OUTDOOR
TEMPERATURE
SENSOR FOR
AUTOMATIC
MODE
• In order for the humidifier to operate, the HVAC blower must
be running and the Model 60 must be calling for humidity.
WIRING DESCRIPTION:
ABOVE EXPECTED
SNOW LINE
• Wire external 24 VAC transformer into a constant power source
other than the heating, ventilating, air conditioning equipment
(HVAC) blower circuit. The transformer can be powered off the
120 VAC line at the junction box before it enters the HVAC
equipment. Connect the 24 volt side of the transformer to one
of the “H” terminals on the humidifier control and to one of the
humidifier solenoid valve wires. Connect the other solenoid
valve wire to the other “H” terminal.
CONNECT
DRAIN LINE
HERE
CONNECT
TO HOT WATER
SUPPLY
R
C
R
C
120 VAC
G
G
Y
Y
CONTINUOUSLY POWERED
24 VAC TRANSFORMER
PROVIDED WITH HUMIDIFIER
W
W
THERMOSTAT
FURNACE
90-1510
• Wire “R” and “C” on the Model 60 to “R” and “C” on the
furnace terminal strip.
• Remove the thermostat “G” wire from the furnace terminal
strip and wire it to “G” on the Model 60 control.
14
15
Download from Www.Somanuals.com. All Manuals Search And Download.
STEP 11: Model 62 Wiring for Model 800 Series Steam
Humidifier – See Figure L
Figure L – Model 62 Wiring for Model 800 Series
Steam Humidifier
WARNING
120/240 volts may cause serious injury from electrical
shock. Disconnect electrical power to the furnace
and humidifier before starting installation.
ADHC TERMINAL STRIP
POWER
INPUTS
OUTPUTS
R
C
A
B
ODT
W
G
H
H
Gf
Strip the wires used for all Humidifier Control terminal
connections 1/4 inch.
MODEL 800
STEAM HUMIDIFIER
NOTES:
OUTDOOR TEMPERATURE SENSOR
FOR AUTOMATIC MODE
• The Model 62 must be continuously powered from “R” and
“C” on the furnace to function properly.
• The minimum VA required is 2.0 VA.
R
C
G
Y
W
R
C
G
Y
W
THERMOSTAT
• In order for the humidifier to operate, the HVAC blower must
be running and the Model 62 must be calling for humidity.
WIRING DESCRIPTION:
FURNACE
• Wire “H” terminals on the Model 62 to the “Humidifier”
terminals on the Model 800 control board.
90-1511
• Wire “R” and “C” on the Model 62 to “R” and “C” on the
furnace terminal strip.
• Remove the thermostat “G” wire from the furnace terminal
strip and wire it to “G” on the Model 62 control.
• Wire “Gf” on the Model 62 to “G” on the furnace terminal
strip.
• Wire “W” on the Model 62 to “W” on the furnace terminal
strip.
• Replace cover and knob.
16
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Blower Activation Test
SYSTEM CHECKOUT
• Deactivate HVAC system or heat pump.
• Turn knob to OFF.
1. Replace the cover by snapping it into the Humidifier Control
base. Also replace the knob onto the Control.
• Set switch to Blower Activation ON.
2. Turn Blower Activation switch to OFF
• Turn the knob to Test/Reset. The Humidifier On light will
illuminate. After 5 seconds, the green “Humidifier On” light
will blink, indicating a system reset.
3. Restore power to the HVAC system.
4. Activate the HVAC system or heat pump (Fan or Heat).
• If the Humidifier Control and humidifier are set up properly,
the solenoid valve should click and the HVAC blower
should activate.
5. Once the blower is operating, rotate the knob of the
Humidifier Control Clockwise to the “Test/Reset” position.
When the knob is set in the “Test/Reset” position, the green
“Humidifier On” light will illuminate. After 5 seconds, the
green “Humidifier On” light will blink, indicating a system
reset.
• If the humidifier does not activate with the Humidifier
Control in the “Test/Reset” position, refer to the
troubleshooting guide.
6. If the Humidifier Control and humidifier are set up properly,
you should hear the solenoid valve click into the open
position. On the Model 800 Steam Humidifier, the “Steam”
light will illuminate green. In the “Test/Reset” position, the
humidifier will operate for 1 minute. If the Humidifier Control
is left in the “Test/Reset” position for more than 1 minute,
the “H” terminals will open (closing the solenoid valve), and
the knob and display backlights will flash, indicating that the
Humidifier Control is still in the “Test/Reset” position.
• If HVAC blower does not activate with the Humidifier
Control in the "Test/Reset" position, refer to the
troubleshooting guide.
8. Setting the Humidifier Control:
• If the home is occupied, set the Humidifier Control to
“Normal”. (For Manual Mode, set to 35%.)
• If the home is vacant, set the Humidifier Control to “OFF”.
• If in Manual Mode and system is installed during cooling
season, set the Humidifier Control to “OFF”.
7. If the humidifier does not activate with the Humidifier Control
in the “Test/Reset” position, refer to the troubleshooting
guide.
9. Instruct the homeowner to refer to the Aprilaire Owner’s
Manual for the initial adjustment period.
10. Make sure the red “Call Dealer for Service” light is not
flashing. If the red “Call Dealer for Service” light is flashing,
refer to the troubleshooting guide.
18
19
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING PROCEDURE (CONTINUED)
TROUBLESHOOTING GUIDE
3. Rotate Humidifier Control knob to the “Test/Reset” position.
After 5 seconds, the green “Humidifier On” light will blink,
resetting the error. If E3 returns, replace the Humidifier
Control.
SYMPTOM
Call Dealer For Service Light Flashing (see Figure M).
TROUBLESHOOTING PROCEDURE
Manual Mode (switch in “MAN” position)
Applies to both Automatic and Manual Operation unless
indicated otherwise.
1. Make sure the ODT terminals are clear of any wires that
may short the terminals together other than the ODT sensor.
Display Error Code: E1: RH Sensor
2. Rotate Humidifier Control knob to the “Test/Reset” position.
After 5 seconds, the green “Humidifier On” light will blink,
resetting the error. If E3 returns, replace the Humidifier
Control.
Rotate Humidifier Control knob to the “Test/Reset” position.
After 5 seconds, the green “Humidifier On” light will blink,
resetting the error. If E1 returns, replace the Humidifier Control.
Display Error Code: E4: Communication
Display Error Code: E2: Control Knob
This error applies to systems wired to an Aprilaire Model 8570
Thermostat (see Figure Q) using the “A” and “B” terminals.
Rotate the Humidifier Control knob to the “Test/Reset”
position. After 5 seconds, the green “Humidifier On” light will
blink, resetting the error. If E4 returns, check the wiring
between the Digital Humidifier Control and Model 8570 check
the connections at “A”and “B” on the humidifier control and
the Model 8570. Make sure the Model 8570 is wired and
operating properly according to the Model 8570 manual.
Rotate Humidifier Control knob to the “Test/Reset” position.
After 5 seconds, the green “Humidifier On” light will blink,
resetting the error. If E2 returns, replace the Humidifier Control.
Display Error Code: E3: Outdoor Temperature Sensor
Auto Mode (switch in “AUTO” position)
1. Make sure that the Outdoor Temperature Sensor is properly
connected to the ODT terminals on the Humidifier Control.
2. Measure the resistance of the Outdoor Temperature Sensor
by removing the leads from the Humidifier Control terminals
and measuring the resistance across the wires with an
ohmmeter. Confirm the reading with the temperature in
Table 1 on page 22. Reconnect the ODT Sensor leads. If the
resistance value does not match the temperature value,
replace the Outdoor Temperature Sensor.
20
21
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE 1
SYMPTOM
Outdoor Temperature (°F) Resistance (kΩ) 10
Humidifier does not operate in “Test/Reset” mode.
-30
-20
-10
0
231.8
163.4
117.3
84.8
62.2
46.1
34.4
26.1
19.9
15.3
11.9
9.3
TROUBLESHOOTING PROCEDURE
• Check wiring diagrams for correct Humidifier Control
installation
10
20
30
40
50
60
70
80
90
100
• Make sure that the blower is operating and the HVAC
system is calling for heat.
• Check wiring diagrams for correct Humidifier Control
installation.
• If connected to a Model 400 Series humidifier, make sure
both floats in the bottom of the scale control insert are in
the down position. If necessary, dump out water to lower
the floats.
7.3
5.8
Figure M
• Check voltage at the Humidifier Control “R” and “C”
terminals. Voltage should be 22 VAC minimum to 30 VAC
maximum.
Red “Call Dealer For Service” Light
Yellow “Change Water Panel” Light
Green “Humidifier On” Light
• Make sure that the saddle valve is open.
• In “Test/Reset mode, the humidifier will operate for 1
minute only. DO NOT LEAVE THE HUMIDIFIER CONTROL IN
“TEST/RESET” MODE AS THE HUMIDIFIER WILL NOT
OPERATE.
90-1227
22
23
Download from Www.Somanuals.com. All Manuals Search And Download.
SYMPTOM
SYMPTOM
Humidifier operates only in “Test/Reset” mode.
Yellow “Change Water Panel” light is blinking (see Figure M).
• If outdoor temperature is greater than 60°F or less than
-30°F, the Humidifier Control will only operate in the
“Test/Reset” mode (for 1 minute).
TROUBLESHOOTING PROCEDURE
Check the condition of the Water Panel and replace it if
mineral deposits are blocking air flow. Follow the instructions
on the Water Panel box. Rotate the knob to the “Test/Reset”
position for at least 5 seconds to reset Water Panel change
timer. Check that the timer setting is correct for the humidifier
model and water conditions (see Figure B). DO NOT LEAVE
THE HUMIDIFIER CONTROL IN “TEST/RESET” MODE AS THE
HUMIDIFIER WILL NOT OPERATE.
• If the humidity level in the home is higher than the
Humidifier Control knob setting, the Humidifier Control will
not operate the humidifier.
TROUBLESHOOTING PROCEDURE
• Measure the resistance of the Outdoor Temperature Sensor
by removing the leads from the Humidifier Control terminals
and measuring the resistance across the wires with an
ohmmeter. Confirm the reading with the temperature in
Table 1. Reconnect the ODT Sensor leads. If the resistance
value does not match the temperature value, replace the
Outdoor Temperature Sensor.
• Make sure that the Outdoor Temperature Sensor is mounted
completely outside the house on the North, East or West
side of the house and out of direct sunlight. (Automatic
Mode Only)
• Make sure that the Outdoor Temperature Sensor is located
at least 3 feet away from all exhaust vents. (Automatic
Mode Only)
• If Outdoor Temperature Sensor is mounted in the fresh air
intake duct, make sure that the sensor is no more than 3
feet from the outside wall. (Automatic Mode Only)
24
25
Download from Www.Somanuals.com. All Manuals Search And Download.
SYMPTOM
SYMPTOM
Humidifier operates constantly.
Humidifier or Humidifier Control “chatters” or clicks On and
Off rapidly.
• If the humidity level in the home is less than the Humidifier
Control knob setting and there is a continuous fan call or
heat call (depending on setup), the Humidifier Control will
operate the humidifier until the humidity level is higher than
the Humidifier Control knob setting.
TROUBLESHOOTING PROCEDURE
• Check for steady 22 VAC to 30 VAC across the “R” and “C”
terminals of the Humidifier Control with a voltmeter.
• Check, with a voltmeter, that the HVAC signal across the
“W” and “C” and “G and C” terminals of the Humidifier
Control is a steady 22 VAC to 30 VAC.
TROUBLESHOOTING PROCEDURE
• Set Blower Activation switch to OFF.
• Make sure that the Outdoor Temperature Sensor wiring is
not running alongside other wires carrying high voltage
(120 VAC or higher). (Automatic Mode Only)
• In the “Test/Reset” mode, verify that the humidifier turns off
after 1 minute.
• Check the Outdoor Temperature Sensor resistance and
location, as instructed on the previous page.
• Rotate the Humidifier Control knob counterclockwise to the
“Off” position, and observe whether the humidifier turns
off. If the humidifier still operates in the “Off” position,
perform the following:
SYMPTOM
Humidifier blower does not activate during Blower Activation
Test.
1. Check the wiring diagram for correct Humidifier Control
Installation.
TROUBLESHOOTING PROCEDURE
• Set the Blower Activation Switch to “ON”.
2. Remove the wires from the “H” terminals on the
Humidifier Control. If the humidifier continues to operate,
replace the solenoid valve.
• Check wiring diagrams for correct Humidifier Control
installation.
26
27
Download from Www.Somanuals.com. All Manuals Search And Download.
RESEARCH PRODUCTS CORPORATION
P.O. BOX 1467 • MADISON,WI 53701-1467
Call 800/334-6011 • FAX 608/257-4357
10008977 6.10
B2205119A
28