Aprilaire Humidifier 600m User Manual

READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING INSTALLATION  
ATTENTION INSTALLER:  
This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock.  
This product must be installed in compliance with all local, state and federal codes.  
Proper humidification and humidity control also requires that the home be constructed in accordance with local codes and good building practices.  
MODEL 600 SERIES HUMIDIFIER  
WARNING  
CAUTION  
SPECIFICATIONS  
RISK OF PROPERTY AND EQUIPMENT DAMAGE.  
1. ELECTRICAL SHOCK HAZARD.  
Disconnect electrical power to the  
furnace before starting installation.  
Failure to do so could result in  
HUMIDIFIER DIMENSIONS  
Width (including solenoid valve): 1538”  
Height (including drain spud): 1534”  
Depth: 1014”  
1. Do not install humidifier where freezing temperatures  
could occur. The water line could freeze and crack  
causing water damage to the home.  
5. Do not connect Model 600 or 600M transformer  
to blower motor wiring. Premature component  
failure may result.  
serious injury from electrical shock.  
2. Do not install humidifier or bypass connection on the  
furnace jacket.  
6. When installing Humidifier Control on  
BYPASS DUCT OPENING  
6” diameter  
downflow furnace, ensure blower continues to  
run after a heat call is satisfied to eliminate  
high temperatures from damaging the Control.  
2. SHARP EDGES HAZARD. Sharp  
edges may cause serious injury from  
cuts. Use care when making plenum  
openings and handling ductwork.  
3. Do not install humidifier or bypass connection on a  
plenum face where the blanked off ends of the cooling  
coil will restrict air movement through the humidifier.  
PLENUM OPENING  
10”W x 1234”H  
7. Do not install humidifier where water pressure  
exceeds 125 psi, since damage to the  
humidifier may result. Follow codes in effect  
concerning pressure reduction.  
4. Do not set humidity level above recommended or to  
recommended level if condensation exists on inside  
windows of any unheated space, as condensation  
damage may result. Excess humidity can cause  
moisture accumulation which can allow the possibility  
for mold growth in the home.  
3. RISK OF SCALDING. Water  
temperature over 125°F can cause  
severe burns and scald instantly.  
Shut off the hot water supply before  
disconnecting or tapping into any  
hot water supply line.  
WATER FEED RATE  
3 gph  
8. Do not install humidifier on systems with  
greater than 0.4 in. wg pressure differential  
between supply and return plenums.  
ELECTRICAL DATA  
24 VAC-60 Hz, 0.5 AMP  
INSTALLATION  
OPTIONS  
RECOMMENDED WIRING DIAGRAMS  
(SEE STEP 7 ON BACK AND “HUMIDIFIER CONTROL SAFETY AND INSTALLATION INSTRUCTIONS” FOR DETAILED WIRING INSTRUCTIONS)  
The Model 600 and 600M Aprilaire can be installed  
on either the supply or return plenum of a forced  
air handling system and is easily reversible for  
installation with right hand or left hand bypass duct  
connections. The humidifier dimensions and  
serviceability must be considered when selecting  
the best location for the humidifier. Here are  
2 examples of many types of installations.  
Model 600  
DIGITAL HUMIDIFIER CONTROL  
ADHC TERMINAL STRIP  
POWER  
INPUTS  
OUTPUTS  
Gf  
R
C
A
B
ODT  
W
G
H
H
NORTH, EAST  
OR WEST SIDE  
OF HOME  
Upflow  
OUTDOOR TEMPERATURE  
SENSOR FOR  
AUTOMATIC MODE  
SUPPLY  
YELLOW WIRES  
R
C
R
ABOVE EXPECTED  
SNOW LINE  
C
RETURN  
G
G
110 VAC  
Y
Y
CONNECT DRAIN  
LINE HERE  
W
CONNECT TO  
HOT WATER SUPPLY  
W
CONTINUOUSLY POWERED  
24 VAC TRANSFORMER  
PROVIDED WITH HUMIDIFIER  
THERMOSTAT  
FURNACE  
90-1510  
IMPORTANT  
Horizontal  
USE 120 VAC POWER SOURCE OTHER THAN FURNACE MOTOR  
CIRCUIT. HOWEVER, THE TRANSFORMER CAN BE POWERED  
OFF THE HOT 120 VAC LINE BEFORE IT ENTERS THE FURNACE.  
Model 600M  
RETURN  
MANUAL CONTROL  
• DO NOT WIRE TRANSFORMER INTO FURNACE BLOWER CIRCUIT.  
24 VAC FURNACE ACCESSORY  
TERMINALS OR TRANSFORMER  
(10VA MINIMUM)  
SHUT-OFF  
(SADDLE VALVE)  
SUPPLY  
WATER SUPPLY  
90-1079  
COMMON  
MODEL 50  
CURRENT SENSING RELAY  
(IF REQUIRED)  
HI  
YELLOW 24V  
SOLENOID  
LO  
VALVE WIRES  
NOTE  
IMPORTANT  
WHEN MODEL 50 CURRENT  
SENSING RELAY IS USED:  
FURNACE  
BLOWER MOTOR  
When installing the Aprilaire humidifier with  
the Aprilaire Digital Humidifier Control or on a  
heat pump system, use hot water. The heated  
water supplements the reduced supply air  
temperature as added heat for evaporation.  
• WIRE MODEL 50 CURRENT  
SENSING RELAY INTO 24 VAC  
HUMIDIFIER CONTROL  
90-1207  
CIRCUIT ONLY! DO NOT  
INSTALL IN TRANSFORMER  
PRIMARY CIRCUIT.  
CONNECT DRAIN LINE HERE  
RESEARCH PRODUCTS CORPORATION • P.O. BOX 1467 • MADISON, WI 53701-1467 • CALL 800/334-6011 • FAX 608/257-4357  