Aprilaire Weather Radio 8056 User Manual

Wireless Outdoor Temperature  
and Humidity Sensor Accessory  
Model 8056  
Wireless Outdoor Temperature  
and Humidity Sensor Accessory for the  
Model 8910 Home Comfort Control™  
Installation and  
Operators Manual  
READ AND SAVE THESE INSTRUCTIONS  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TAblE Of CONTENTS  
INSTAll bATTERIES INTO WIRElESS OUTDOOR SENSOR  
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
Install Batteries into Wireless Outdoor Sensor . . . . 3  
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
Error Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
FCC Declaration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
IC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
1. Remove the cover of Wireless Outdoor  
Sensor to access battery compartment.  
See figure 1.  
fIGURE 1  
Installation of Wireless Module into  
8910 Equipment Control Module. . . . . . . . . . . . . . . . 4  
2. Install two fresh Lithium AA sized  
batteries. Batteries included.  
How to Link Wireless Outdoor Sensor . . . . . . . . . . . 6  
How to Mount the Wireless Outdoor Sensor . . . . . . 8  
3. Replace cover.  
fEATURES  
In heat pump mode the Wireless Outdoor Sensor can be used to efficiently utilize an air source  
heat pump.  
•When the outdoor temperature is less than the Low Balance Point, the heat pump will be locked out and only  
auxiliary heating will be used.  
•When the outdoor temperature is higher than the High Balance Point, the auxiliary heating will be locked  
out and only heat pump will be used to provide heating.  
Indoor Air Quality functions can use the Wireless Outdoor Sensor.  
•Control humidification setpoint based on outdoor temperature to prevent condensation.  
•Lock out humidification for temperatures over 60°F or below -30°F.  
•Lock out ventilation based on high and/or low outdoor temperatures.  
•Display outdoor temperature and humidity on thermostat.  
90-1788  
2
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
fIGURE 3  
INSTAllATION Of WIRElESS MODUlE INTO  
8910 EQUIpMENT CONTROl MODUlE  
1. Disconnect power to 8910  
Equipment Control Module.  
fIGURE 2  
VIEW THRU WINDOW  
TO ALIGN PINS  
2. Remove cover from 8910  
Equipment Control Module.  
3. Remove and discard 8910  
Equipment Control Module  
wireless slot cover. See  
figure 2.  
4. Insert Wireless Module into  
8910 Equipment Control  
Module. See figure 3.  
5. Replace cover on 8910  
Equipment Control Module.  
6. Reconnect power to the  
8910 Equipment Control  
Module.  
90-1786  
90-1785  
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
fIGURE 5  
HOW TO lINk WIRElESS OUTDOOR SENSOR  
1. Remove the cover of Wireless Outdoor Sensor and  
8910 Equipment Control Module.  
fIGURE 4  
2. Press and hold the link button on the Wireless Outdoor  
Sensor for 3 seconds, the green LED will begin to flash  
slowly. See figure 4. The Sensor is now in linking mode  
and will wait 5 minutes for a linking signal.  
3. Now press and hold the link button on the 8910 Equipment  
Control Module for 3 seconds (see figure 5), both green  
LEDs on the sensor and control module will begin to  
flash rapidly indicating the units are in the process  
of linking. Then both green LEDs will go solid for 2  
minutes then off. The modules are now linked.  
Note: If the 8910 does not already have the  
outdoor sensor enabled you will need to enable  
by setting system setting #11 OUTDOOR  
SENSOR of the Installer system settings to YES  
at the 8910 user interface.  
Note: If a wired outdoor sensor is already installed,  
the wireless outdoor sensor will take priority. If a  
wireless outdoor sensor error occurs, the 8910 will  
display the corresponding error and revert to the wired  
outdoor sensor reading.  
90-1793  
90-1788  
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
fIGURE 6  
fIGURE 7  
HOW TO MOUNT THE WIRElESS OUTDOOR SENSOR  
1. Select a mounting location,  
3. Mount bracket with the appropriate  
type of screws (not supplied).  
See figure 6.  
• Within 100 feet of the 8910 Equipment Control Module. (Range varies with building material types.)  
• Away from large metal obstructions that could reduce wireless communication range.  
• Away from direct rainfall (the unit is water resistant not water proof).  
• On a vertical exterior wall, at least 6 inches below any overhang.  
• Protected from direct sunlight (north side recommended).  
• At least 3’ away from exhaust vents and condensing lines.  
• Above the snow line.  
4. Insert sensor onto bracket and slide  
down to secure. See figure 7.  
90-1783  
• Accessible for easy battery replacement.  
2. IMpORTANT: Confirm the wireless connection at the desired location prior to installing the  
mounting bracket. To confirm the wireless connection, place the wireless outdoor sensor near the  
desired mounting location. Confirm the outdoor temperature and RH continue to display at the 8910 user  
interface and there are no wireless outdoor sensor errors.  
Note: If there is a problem with the wireless connection, it will take up to 10 minutes for the temperature  
and RH to stop displaying and wireless error codes to appear (see ERROR CODES section for more details).  
It is recommended that you wait 10 minutes before proceeding to step 3.  
90-1784  
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
SpECIfICATIONS  
fIVE YEAR lIMITED WARRANTY  
Your Research Products Corporation Aprilaire® Wireless Outdoor Temperature and Humidity Sensor is expressly warranted for five (5) years from  
date of installation to be free from defects in materials or workmanship.  
Communications  
Wireless 900 MHz  
Wireless range  
Up to 100 feet  
Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any sensor  
which is found to be defective within such five (5) year period and which is returned, together with the date of installation, no later than thirty  
(30) days after said five (5) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701.  
Temperature measurement range / accuracy  
Humidity measurement range / accuracy  
Battery life  
-31°F to 135°F / ±3°F accuracy (0°F to 120°F)  
0%RH to 100%RH / ±5%RH accuracy (20%RH to 80%RH)  
Approximately 2 years  
THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS  
IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE SENSOR ITSELF.  
IMPLIED WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID  
FIVE YEAR PERIOD. RESEARCH PRODUCTS CORPORATION’S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN  
DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED  
WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE THIS SENSOR  
INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE  
A QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION.  
Battery type  
2x Lithium AA size 1.5V  
ERROR CODES  
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages,  
so the above exclusions or limitations may not apply to you.  
The 8910 can display these error codes related to the Wireless Outdoor Sensor:  
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.  
“CHECK WIRELESS  
OUTDOOR SENSOR”  
The 8910 Equipment Control Module cannot connect to Wireless Outdoor sensor. Confirm  
This equipment if installed in strict accordance with the manufacturer’s instructions, complies with the limits for a Class B computing device  
pursuant to Subpart J of Part 15 of FCC Rules.  
batteries are good and installed correctly. Confirm sensor location is not an issue by  
bringing the sensor closer to the Equipment Control Module or away from potential  
interference. Then follow the linking procedure to reconnect.  
WARRANTY REGISTRATION  
“REPLACE WIRELESS  
SENSOR BATTERY”  
Low Batteries in Wireless Outdoor Sensor. Replace batteries in the Sensor with Lithium  
size AA 1.5V only.  
Visit us on-line at www.aprilaire.com to register your Aprilaire product. If you do not have on-line access, please mail a postcard with your  
name, address, phone number, product purchased and date of purchase to: Research Products Corporation, P.O. BOX 1467, Madison, WI 53701  
“CHECK ECM  
WIRELESS MODULE”  
The 8910 Equipment Control Module cannot detect the Wireless Module. Follow the  
installation procedure; reinstall the Wireless Module into the Equipment Control Module.  
Then follow the linking procedure to reconnect.  
Your Warranty Registration information will not be sold or shared outside of this company.  